SDI Logo
Organization
Kabupaten Nias Selatan

Badan Riset dan Inovasi Nasional

Informasi Dataset

07-11-2022

13-08-2024

23918b40-e3be-4384-b5a5-ecebfcd52ed1

Dataset Serupa
Validation of a field-friendly extraction and storage method to monitor fecal st...

Measuring hormone metabolites from feces is the most often used method to assess...

Comparison of Two Analytical Methods for Compositional Analysis of Lignocellulos...

Empty fruit bunch (EFB) of oil palm is one of potential lignocellulosic biomass ...

Analysis of Librarians in the Research Data Services for Research and Developmen...

Penelitian ini bertujuan untuk mengetahui persepsi Pustakawan terkait Layanan Da...

Analysis of Librarians in the Research Data Services for Research and Developmen...

Penelitian ini bertujuan untuk mengetahui persepsi Pustakawan terkait Layanan Da...

A Comparison of Extraction Techniques for the rapid EEG-P300 Signals

In this paper, three different methods for brain signal acquisition are presente...

INFORMASI: Data berikut ini masih dalam proses pemenuhan Prinsip SDI.

Comparison Of Fecal Preservation And Extraction Methods For Steroid Hormone Metabolite Analysis In Wild Crested Macaques

Terbatas

Since the non-invasive field endocrinology techniques were developed, several fecal preservation and extraction methods have been established for a variety of species. However, direct adaptation of methods from previous studies for use in crested macaques should be taken with caution. We conducted an experiment to assess the accuracy and stability of fecal estrogen metabolite (E1C) and glucocorticoid metabolite (GCM) concentrations in response to several preservation parameters: (1) time lag between sample collection and fecal preservation; (2) long-term storage of fecal samples in 80 persen methanol (MeOH) at ambient temperature; (3) different degrees of feces drying temperature using a conventional oven; and (4) different fecal preservation techniques (i.e., freeze-drying, oven-drying, and field-friendly extraction method) and extraction solvents (methanol, ethanol, and commercial alcohol). The study used fecal samples collected from crested macaques (Macaca nigra) living in the Tangkoko Reserve, North Sulawesi, Indonesia. Samples were assayed using validated E1C and GCM enzyme immunoassays. Concentrations of E1C and GCM in unprocessed feces stored at ambient temperature remained stable for up to 8 h of storage after which concentrations of both E1C and GCM changed significantly compared to controls extracted at time 0. Long-term storage in 80 persen MeOH at ambient temperature affected hormone concentrations significantly with concentrations of both E1C and GCM increasing after 6 and 4 months of storage, respectively. Drying fecal samples using a conventional oven at 50, 70, and 90 °C did not affect the E1C concentrations, but led to a significant decline for GCM concentrations in samples dried at 90 °C. Different fecal preservation techniques and extraction solvents provided similar results for both E1C and GCM concentrations. Our results confirm previous studies that prior to application of fecal hormone analysis in a new species, several preservation parameters should be evaluated for their effects on hormone metabolite stability. The results also provide several options for fecal preservation, extraction, and storage methods that can be selected depending on the condition of the field site and laboratory. Primates 2018

Data and Resources

Metadata

Version
Produsen Data
Email Produsen Data
Walidata
Email Walidata
Periode Data
Akses Data
Kode Daftar Data
Kode Indikator MMS
Kode Standar Data
Satuan
Ukuran
Jenis Data
Kategori
Data Prioritas
Kriteria Prioritas
Indikator Prioritas
Kode Metadata Kegiatan