SDI Logo
Organization
Kabupaten Nias Selatan

Badan Riset dan Inovasi Nasional

Informasi Dataset

07-11-2022

13-08-2024

87d5d492-4c14-4cc1-b9d6-8de3849c89ab

Dataset Serupa
Investigation of Corrosion Protection of Rebar Steel Using Organic Inhibitor in ...

Rebar steel embedded in concrete is naturally protected against corrosion by pas...

Study of pitting resistance of rebar steels in jakarta coastal using simulated c...

Carbon steels are generally used to a reinforcement in the concrete construction...

Study of Pitting Resistanceof rebar steels in jakarta coastal using simulated co...

Carbon steels are generally used to a reinforcement in the concrete construction...

Light-weight cementitious conductive anode for impressed current cathodic protec...

This paper presents the results of a study of the effectiveness of lightweight c...

The Selection of Magnesium alloys as Sacrificial Anode for the Cathodic Protecti...

Various characterization 4 type of Mgsacrificial anodes (A,B,C and D from differ...

INFORMASI: Data berikut ini masih dalam proses pemenuhan Prinsip SDI.

Corrosion Behaviour of Cathodically Protected Rebars Steel in Simulated Concrete Pore Solution

Terbatas

Corrosion behaviour of cathodically protected rebars steel was observed in simulated concrete pore solution. In The previous study, zinc alloy and aluminium alloy are commonly used to sacrificial anode system for protection of steel in concrete. The use of pure zinc anode for the above purpose is limited. This study has been carried out with a view to analyse the use of pure zinc anode for the cathodic protection of steel in simulated concrete pore solution and pH 13. The electrochemical measurement was performed on cathodically protected rebars steel as working electrode, Saturated Colomel Electrode (SCE) as reference electrode and graphite as counter electrode to evaluate open circuit potential for 2 hours, corrosion potential and corrosion rate behaviour after 2 hours. The The relationships between the protection potential with time, corrosion potential and corrosion rate after 2 hours, sacrificial anode life, discharge currents, and capacity of sacrificial anodes were found. According to the results obtained, The best selection of sacrificial anode was pure Zn anode with resistor of 600 Ohm. Proceeding of The 2nd International Conference on Materials and Metallurgical Technology (ICOMMET) 2015.

Data and Resources

Metadata

Version
Produsen Data
Email Produsen Data
Walidata
Email Walidata
Periode Data
Akses Data
Kode Daftar Data
Kode Indikator MMS
Kode Standar Data
Satuan
Ukuran
Jenis Data
Kategori
Data Prioritas
Kriteria Prioritas
Indikator Prioritas
Kode Metadata Kegiatan